Please remove $0 item(s) from cart - or - Request for Quote

Dell PowerEdge T610 CTO Tower Server

Brand:
Type:
CTO Servers
Condition:
ECS Refurbished & Tested
-PLEASE CONTACT FOR CUSTOM CONFIGURATIONS. DISK SHELVES, COMPLETE CONFIGURATIONS & TURN KEY SYSTEMS AVAILABLE.
-SPARE PARTS AVAILABLE FOR EACH MODEL. PLEASE ASK FOR PRICING ON SPARE DISK, CONTROLLERS, POWER SUPPLIES, NICs, HBAs, SFPs, Cables, etc.

READ ME

  • Some options may not be displayed until the compatible parent option is chosen ie. Chassis – Drives, Processor – RAM etc.
  • “Submit for Quote” items can be added to your cart and sent to us via the cart page
  • Click the blue bar to close/open a section from view after choosing your options

Server Chassis

Processors

Intel Xeon 5500

Supports up to (2) PSU's

Intel Xeon 5600

Supports up to (2) PSU's

Memory

6 DIMMs per processor (up to 12 DIMMs in a dual-processor configuration)

Internal Dual SD Module (IDSDM) (Optional)

RAID Controllers (Optional)

LFF (3.5") SAS/NLSAS Drives (Optional)

LFF (3.5") SATA Drives (Optional)

PCIe Riser Full Height (Optional)

5 PCIe Slots (Full Height)

iDRAC Remote Options (Optional)

Power Supplies

Supports up to (2) PSU's

Optical Drive (Optional)

Security (Optional)

ECS Warranty

Helpful Tip: Once desired configuration is selected click "Add to Cart". From the cart page you can submit a submit a quote request for best pricing

Dell PowerEdge T610 CTO Tower Server

Quick Specs

Form Factor:

Tower server | 5U (Rack conversion kit)

Processor | Max: 6 Cores (PP)

2x Intel Xeon 5500 or 5600 Processors

Memory | Max: 192GB

12 DDR3 RDIMM 1333Mhz

Storage | Max: 24TB

8x 3.5” or 2.5" SAS/NL-SAS/SATA (HDD/SSD)

Boot Options

IDSDM
Internal USB

RAID Controller:

S100 & S300 (SW RAID)
H200, H700, PERC6/i
External
H800, PERC 6/E
External (non-RAID)
6Gbps SAS HBA, SAS 5/E HBA, LSI2032 PCIe SCSI HBA

NIC/LOM

2 x 1GbE LOM

Remote Management:

iDRAC6

PCIe Slots:

5 PCIe G2 slots + 1 storage slot
Two x8 slots
Three x4 slots
One x4 storage slot

GPU:

Not Supported

The Dell PowerEdge T610 server is a key data center building block for IT professionals seeking the highest level of performance, availability, and expandability in a 2-socket server.

Ideally suited for small and medium businesses and remote office customers, the T610 delivers enhanced virtualization, improved design, and energy efficiency in a server engineered to address both your current and future business needs.


Strong IT Foundation

A solid IT foundation is critical for business success. The Dell PowerEdge T610 contributes to your IT foundation by offering many of the virtualization, system management, and usability capabilities you need while providing impressive power and thermals for overall energy efficiency. This mainstream two socket Intel™ based tower server includes a rack-mount option and supports mission critical applications and data processing.


Purposeful Design

The T610 takes advantage of Dell’s system commonality. Once your IT managers learn one system, they understand how to manage next-generation Dell servers. Logical component layout and power supply placement also provide a straightforward installation and redeployment experience. Inspired by IT professionals, the T610 is built to simplify daily operations and maximize uptime.

In addition, Dell PowerEdge servers provide a graphical and interactive LCD for system health monitoring, alerting, and control of basic management configuration right in the front of the server. Customers have an AC power meter and ambient temperature thermometer built into the server that they can monitor on this display without any software tools.


Energy-Optimized Technology

Using the latest Energy Smart technologies, the T610 helps reduce power consumption while increasing performance capacity over previous generations of Dell towers. Enhancements include efficient power supply units right-sized for system requirements, effective system-level design efficiency, policy-driven power and thermal management, and highly efficient standards-based Energy Smart components. These features are designed to maximize energy usage across our latest core data center servers without compromising performance.


Advanced Virtualization

Featuring Intel Xeon processor 5500 and 5600 series, embedded hypervisors, 100% integrated I/O, and up to 100% more memory capacity than the previous server generations, the Dell PowerEdge T610 delivers better overall system performance and greater virtual machine-per-server capacity than ever before.

With optional factory-integrated virtualization capabilities, you get tailored solutions—built with the latest industry-standard technologies from Dell and our trusted partners—which allow you to streamline deployment and simplify virtual infrastructures. Choose your hypervisor from market leaders such as VMware, Citrix, and Microsoft, and enable virtualization with a few mouse clicks.

Cooling & Fans

With the ability to install one or two Processors in this Dell PowerEdge T610 with no high-performance accelerators or adapter cards. The system only comes with one type of Heat Sink for the Intel CPUs.

The Fan system in the Dell T610 comes with 2 Large fans in the rear of the system providing the optimal air-flow across all the components.

Image of the fan assembly in the dell poweredge T610 Tower Server
Memory

The PowerEdge T610 utilizes DDR3 memory, providing a high-performance, high-speed memory interface capable of low latency response and high throughput. The T610 supports Registered ECC DDR3 DIMMs (RDIMM) or Unbuffered ECC DDR3 DIMMs (UDIMM).

The PowerEdge T610 has 12 DIMM slots for memory. The DDR3 memory interface consists of three channels with up to two RDIMMs or UDIMMs per channel for single- or dual-rank and up to two RDIMMs per channel for quad-rank. The interface uses 2GB, 4GB, 8GB, or 16GB RDIMMs. Also supported are 1GB or 2GB UDIMMs.

DIMM Rules
  • Registered (RDIMM) and Unbuffered (UDIMM) DDR3 technology
  • Support for up to 192 GB of RDIMM memory (twelve 16 GB RDIMMs)
  • Support for up to 24 GB of UDIMM memory (twelve 2 GB UDIMMs)
  • RDIMMs and UDIMMs cannot be mixed.
  • Support for Advanced ECC mode
  • Support for Memory Optimized mode
  • Support for Memory Mirroring
  • For all the rules please read the manuals below.
PCI Configuration

The PowerEdge T610 has five PCI Express expansion slots and one dedicated storage slot, which are detailed as follows:

  • Two x8 PCIe Gen2 slots for full-height full-length cards connected to the IOH
  • Three x4 PCIe Gen2 slots for full-height half-length cards connected to the IOH
  • One x4 PCIe Gen1 slot for a dedicated storage controller card connected to the IOH

The system supports 25W maximum power for the first two PCIe cards and 15W for the third, fourth, and fifth PCIe cards. The lower-power support on the third, fourth, and fifth cards is due to system thermal limitations and not due to system power requirements.
The system does not support hot-plugging or hot-removal of PCI Express cards.

Networking

The PowerEdge T610 has an embedded dual-port Gigabit Ethernet controller with TCP Offload Engine (TOE) support. The embedded Broadcom® 5709C dual-port LAN controller is on the T610 planar as an independent Gigabit Ethernet interface device. The following information details the features of the LAN device:

  • x4 PCI Express Gen2 capable interface (controller operated at Gen1 speed)
  • Integrated MAC and PHY
  • Wake-On-LAN (WOL)
  • PXE 2.0 remote boot
  • iSCSI boot
  • Bare metal deployment support
Storage Controllers
Product Usage T610 Support Slot PCIe Con PCI Bracket I/O Con RAID Battery Backup
PERC SAS/ SATA PERC 6/i Integrated (PERC H700) Internal Backplane Storage (HDD, SSD) Yes—Max 1 Storage slot x8 No x4 int
x4 int
0, 1, 5, 6, 10, 50, 60 Yes
PERC 6/E Adapter (PERC H800) External SAS / SATA Storage Yes—Max 2 (MD1000 and MD1020) PCIe slot x8 Yes x4 ext
x4 ext
0, 1, 5, 6, 10, 50, 60 Yes
PERC 5/E Adapter External Legacy Storage Yes—Max 2 (MD1000 only) PCIe slot x8 Yes x4 ext
x4 ext
0, 1, 5, 10, 50 Yes
SAS HBA SAS/ SATA SAS 6/iR Integrated (PERC H200) Internal Backplane Storage (No tape or SSD support) Yes—Max 1 Storage slot x8 No x4 int
x4 int
0, 1 No
SAS 5/iR Adapter Internal SAS tape Yes—Max 2 PCIe slot x8 Yes x4 int N/A No
SAS 5/E Adapter (SAS 6G HBA) External SAS (DAS, tape) Yes—Max 2 PCIe slot x8 Yes x4 ext
x4 ext
None No
ICH SATA On Planar via chipset Internal SATA optical/tape (No HDD) Yes—2 ports for Optical and/or Tape N/A N/A N/A x1 int N/A N/A
LSI SCSI LSI 2032 Adapter Internal/External SCSI tape or external legacy SCSI storage Yes—Max 2 PCIe slot x4 Yes x1 int
x1 ext
N/A N/A
A maximum of 2 external storage controllers (Dell PERC and SAS cards) are allowed in the system in addition to the integrated storage controller.
Power & Dimensions
Power Supply Unit (PSU)
Feature Specification
Wattage 870 Watt (high output)
570 Watt (Energy Smart)
Voltage 90-264 VAC, autoranging, 47-63Hz
Maximum inrush current Under typical line conditions and over the entire system ambient operating range, the inrush current may reach 55A per power supply for 10ms or less.
Dimensions
Configuration Height Width Depth Weight (max config) Weight (empty)
Rack 217.7mm (8.57in) 482.5mm (19in) 621mm (24.4in) 35kg (77lb) 20.2kg (44.53lb)
Tower 441mm (17.4in) 274mm (10.8in) 621mm (24.4in) 35kg (77lb) 20.2kg (44.30lb)
 

Current Configuration

Server Chassis

None

Processors

None

Memory

None

Internal Dual SD Module (IDSDM) (Optional)

None

RAID Controllers (Optional)

None

LFF (3.5") SAS/NLSAS Drives (Optional)

None

LFF (3.5") SATA Drives (Optional)

None

PCIe Riser Full Height (Optional)

None

iDRAC Remote Options (Optional)

None

Power Supplies

None

Optical Drive (Optional)

None

Security (Optional)

None

ECS Warranty

None
*list also serves as quick links to each section

Price as Configured: $0.00

Welcome to the Request Express Quoting Form!

for: Dell PowerEdge T610 CTO Tower Server


This streamlined form is designed to simplify the quoting process for you. Whether you're uncertain about specific parts or seeking a hassle-free experience, you're in the right place.

Provide us with the necessary details, and we'll generate a customized quote for your server. Even if you're unsure about the exact components you need, we've got you covered. Our team will tailor a solution based on the information you provide.

Let's get started!
Simply fill out the form, and we'll take care of the rest.


Name *
Email *
Message *
Preferred Brand
Form Factor
Rack Unit of Height (#U)
Processor(s)
Memory
Total Amount of Memory
Total Amount of Usable Storage

Storage Type


RAID

List Networking Connection needed:
Rack Space Restrictions
Which OS do you plan on using:


Add to Cart

Please select at least 1 item from the configuration list before adding to cart

Product Specs

Base Standard Capabilities

FeaturePowerEdge T610 Technical specification
Form FactorTower or 5U rack
ProcessorsQuad-core or six-core Intel® Xeon® processors 5500 and 5600 series
Processor Sockets2
Front Side Bus or HyperTransportIntel® QuickPath Interconnect (QPI)
CacheUp to 12MB
ChipsetIntel® 5520
MemoryUp to 192GB (12 DIMM slots): 1GB/2GB/4GB/8GB/16GB DDR3 up to 1333Mhz
I/O Slots5 PCIe G2 slots + 1 storage slot:
Two x8 slots
Three x4 slots
One x4 storage slot
RAID ControllerInternal:
PERC H200 (6Gb/s)
PERC H700 (6Gb/s) with 512MB battery-backed cache;
512MB, 1GB Non-Volatile battery-backed cache
SAS 6/iR
PERC 6/i with 256MB battery-backed cache
PERC S100 (software based)
PERC S300 (software based)
External:
PERC H800 (6Gb/s) with 512MB of battery-backed cache;
512MB, 1GB Non-Volatile battery-backed cache
PERC 6/E with 256MB or 512MB of battery-backed cache
External HBAs (non-RAID):
6Gbps SAS HBA
SAS 5/E HBA
LSI2032 PCIe SCSI HBA
Drive Bays8 x 2.5” Hard Drive Option or 8 x 3.5” Hard Drive Option;
Optional support half-height TBU
Maximum Internal StorageUp to 16TB
Hard DrivesHot-plug Hard Drive Options:
2.5” SAS SSD, SATA SSD, SAS (15K, 10K), nearline SAS (7.2K), SATA (7.2K)
3.5” SAS (15K, 10K), nearline SAS (7.2K), SATA (7.2K)
CommunicationsOne dual-port embedded Broadcom® NetXtreme® II 5709c Gigabit
Ethernet NIC with failover and load balancing.
Optional 1GBe and 10GBe Add-In NICs:
Broadcom® NetXtreme® II 57711 Dual Port Direct Attach 10Gb Ethernet PCI-Express Network Interface Card with TOE and
iSCSI Offload
Intel® Gigabit ET Dual Port Server Adapter and Intel® Gigabit ET quad port server adapter
Dual Port 10GB Enhanced Intel® Ethernet Server Adapter X520-DA2 (FcoE ready for future enablement)
Brocade® CNA dual-port adapter
Emulex® CNA iSCSI HBA stand up adapter OCE10102-IX-D
Brocade® FC4 and 8 GB HBAs
Power SupplyTwo Hot plug redundant PSUs - Energy Smart PSU (570W) or two hotplug 870W PSUs
AvailabilityDDR3 memory; ECC; hot-plug hard drives; optional hot-plug redundant power supplies; dual embedded NICs with
failover and load balancing support; optional PERC6/i integrated daughtercard controller with battery-backed cache; hotplug
redundant cooling; tool-less chassis; fibre and SAS cluster support; validated for Dell/EMC SAN
VideoIntegrated Matrox G200 with 8MB shared video memory
Remote ManagementiDRAC6
Systems ManagementDell™ OpenManage™
Rack SupportReadyRails™ sliding rails with optional cable management arm for 4-post racks (optional adapter brackets required for
threaded hole racks)
Operating SystemsMicrosoft® Windows® Small Business Server 2011
Microsoft® Windows® Small Business Server 2008
Microsoft Windows Server® 2008 SP2, x86/x64 (x64 includes Hyper-V™)
Microsoft Windows Server® 2008 R2, x64 (includes Hyper-V™ v2)
Microsoft® Windows® HPC Server 2008
Novell® SUSE® Linux Enterprise Server
Red Hat® Enterprise Linux
Oracle® Solaris™
Virtualization Options:
Citrix® XenServer™
VMware® vSphere™ 4.1 (including VMware ESX® 4.1 or VMware ESXi™ 4.1)
For more information on the specific versions and additions, visit www.dell.com/OSsupport.
Featured Database ApplicationsMicrosoft® SQL Server® solutions (see Dell.com/SQL)
Oracle® database solutions (see Dell.com/Oracle)

Compare Servers

Feature T410 T610 T710
Processor Intel Xeon processor 5500 and 5600 series Intel Xeon processor 5500 and 5600 series Intel Xeon processor 5500 and 5600 series
Front Side Bus 6.4 GT/s QuickPath Interconnect (QPI) links 6.4 GT/s QuickPath Interconnect (QPI) links 6.4 GT/s QuickPath Interconnect (QPI) links
Number of Sockets 2 2 2
Number of Cores 2, 4, or 6 2, 4, or 6 2, 4, or 6
L2/L3 Cache 4MB, 8MB, and 12MB 4MB, 8MB, and 12MB 4MB, 8MB, and 12MB
Chipset Intel 5500 Intel 5520 Intel 5520
DIMMs 8 x DDR3 12 x DDR3 18 x DDR3
Min/Max RAM 1GB/128GB 1GB/192GB 1GB/192GB
Drive Bays Optional hot-plug 6 x 2.5" or 6 x 3.5" Hot-plug 8 x 2.5" or 8 x 3.5" Hot-plug 16 x 2.5" or 8 x 3.5"
Hard Drive Types SATA SSD, SAS, nearline SAS, SATA SAS SSD, SATA SSD, SAS, nearline SAS, SATA SAS SSD, SATA SSD, SAS, nearline SAS, SATA
External Drive Bays 2 x 5.25" 2 x 5.25" 2 x 5.25"
Embedded Hard Drive Controller PERC H200, PERC H700, SAS 6/iR, PERC 6/i, PERC S100, PERC S300 PERC H200, PERC H700, SAS 6/iR, PERC 6/i, PERC S100, PERC S300 PERC H200, PERC H700, SAS 6/iR, PERC 6/i, PERC S100, PERC S300
Optional Storage Controller Non-RAID: SAS 5/E LSI 2032 (for tape backup unit only) 6Gbps SAS HBA RAID: SAS 6/iR PERC H200 PERC 6/i PERC H700 PERC 6/E PERC H800 Non-RAID: SAS 5/E LSI 2032 (for tape backup unit only) 6Gbps SAS HBA RAID: SAS 6/iR PERC H200 PERC 6/i PERC H700 PERC 6/E PERC H800 Non-RAID: SAS 5/E LSI 2032 (for tape backup unit only) 6Gbps SAS HBA RAID: SAS 6/iR PERC H200 PERC 6/i PERC H700 PERC 6/E PERC H800
Availability Optional hot-plug hard drives Optional hot-plug redundant power ECC memory Memory mirroring Quadpack LED or LCD diagnostic Hot-plug hard drives Optional hot-plug redundant power Optional redundant cooling ECC memory Memory mirroring LCD diagnostic One dual-port embedded NIC with TOE Hot-plug hard drives Optional hot-plug redundant power Hot-plug redundant cooling ECC memory Memory mirroring LCD diagnostic Two dual-port embedded NICs with TOE
Server Management Baseboard Management Controller (BMC), IPMI 2.0, Dell OpenManage™ Optional: iDRAC6 Express, iDRAC6 Enterprise, vFlash media Baseboard Management Controller (BMC), IPMI 2.0, Dell OpenManage™, iDRAC6 Express Optional: iDRAC6 Enterprise, vFlash media Baseboard Management Controller (BMC), IPMI 2.0, Dell OpenManage™, iDRAC6 Express Optional: iDRAC6 Enterprise, vFlash media
I/O Slots 4 PCIe x8 (x4 routing) 1 PCIe x16 (x8 routing) 2 PCIe x8 3 PCIe x4 Gen 2 1 PCIe x16 4 PCIe x8 1 PCIe x4
NIC/LOM Broadcom ® BCM5716 2 x GbE Optional: various NICs available Broadcom® BCM5709c 2 x GbE with TOE Optional: various NICs available Broadcom® BCM5709c 4 x GbE with TOE Optional: various NICs available
USB 2 front, 4 back, 1 internal 2 front, 6 back, 1 internal 2 front, 6 back, 1 internal
Power Supplies Non-redundant 525W or Optional hot-plug redundant 2 x 580W Hot-plug redundant 2 x 570W (Energy Smart) or 2 x 870W (High-output) Hot-plug redundant 2 x 1100W
Fans Non hot-plug, nonredundant Non hot-plug, nonredundant Hot-plug redundant

Shipping Information

Express Computer Systems can ship to virtually any address in the world and provides you with the best shipping rates possible. Cost of shipping varies depending on what service you require, your destination and size of the shipment. Shipping costs will be calculated separately from your order and billed to you post purchase. In the notes section of your order please provide us with your preferred shipping method and we will get back to you.

Custom configured orders ship within 2 business days after all required products are in stock.

Please allow 3 business days for products that are not in stock to arrive to our facility in Irvine, California.

Domestic Shipments
  • Standard Ground
    • Shipping time: 2-7 business days
    • Order processing time: 0-3 business days
    • Delivery time after order is placed: 2-10 business days
    • Excludes weekends, holidays or weather delays.
  • 3 Business Days
    • Shipping time: 3 business days
    • Order processing time: 0-3 business days
    • Delivery time after order is placed: 3-6 business days
    • Excludes weekends, holidays or weather delays.
  • 2 Business Days
    • Shipping time: 2 business days
    • Order processing time: 0-3 business days
    • Delivery time after order is placed: 2-5 business days
    • Excludes weekends, holidays or weather delays.
  • Overnight / Next Business Day
    • Shipping time: 1 business days
    • Order processing time: 0-3 business days
    • Delivery time after order is placed: 1-4 business days
    • Excludes weekends, holidays or weather delays.
International Shipments
  • International Economy
    • Shipping time: 4-6 business days
    • Order processing time: 0-3 business days
    • Delivery time after order is placed: 5-9 business days
    • Excludes weekends, holidays or weather delays.
  • International Priority
    • Shipping time: 1-3 business days
    • Order processing time: 0-3 business days
    • Delivery time after order is placed: 2-6 business days
    • Excludes weekends, holidays or weather delays.

For more information on shipping view our Shipping Information page or send us a message

ECS Warranty Information

Express Computer Systems (ECS) provides a 1 year parts warranty against defects in material or workmanship that will affect the products functionality. All refurbished items are tested prior to shipping to guarantee up-time upon arrival. If you are having issues with an item we provided please Contact Us and we will do our best to assist you.

What does our ECS warranty cover?
We offer 1 year warranty as standard and additional years can be added to fit your needs. Please reach out to a sales associate via the Contact Us page or live chat for more information on extended coverage options. During the coverage period if your product fails we will offer a Next Business Day replacement. If we are unable to replace the product we will refund its original selling price. Shipping costs and tax are not refundable. Express Computer Systems retains the right to decide whether the goods will be replaced or refunded.

What is not covered by our warranty?
Our warranty does not cover any problem caused by the following conditions:

  1. accidents; misuse; carelessness; electrostatic discharge; shock; temperature or humidity beyond the specifications of the product; improper installation; operation; modification;
  2. any improper use that contravenes the instructions in the user manual;
  3. problems caused by other equipment. Our warranty is void if the product is returned with damaged, removed, counterfeit labels, or any modifications (including any component or external cover removal). Our warranties do not cover data loss or damages to any other equipment. In addition, our warranties do not cover incidental damages, consequential damages, or costs related to data recovery, removal, and installation.

Important notes:

  • Please ask for additional warranty/coverage that you may require in addition to the standard 1 ECS warranty prior to final purchase. Requesting additional warranty after your purchase can be denied.
  • FREE technical support is provided on purchased items via phone, email, or live chat.

About Express Computer Systems

Express Computer Systems is committed to transforming our customers’ IT infrastructure with high quality products at affordable costs. Our sales reps and customer support engineers understand our customers rely heavily on advanced technology to run their business but need to do so without breaking the bank.

We specialize in building custom server configurations, custom storage solutions, networking solutions, and components from top manufacturers including HPE, Dell, Cisco, NetApp, Dell EMC, HPE Nimble and many others.

Subscribe