Please remove $0 item(s) from cart - or - Request for Quote

Cisco UCS C240 C-Series M4 12x 3.5" LFF Rack Servers CTO

Brand:
Type:
CTO Servers
Condition:
ECS Refurbished & Tested
-PLEASE CONTACT FOR CUSTOM CONFIGURATIONS. DISK SHELVES, COMPLETE CONFIGURATIONS & TURN KEY SYSTEMS AVAILABLE.
-SPARE PARTS AVAILABLE FOR EACH MODEL. PLEASE ASK FOR PRICING ON SPARE DISK, CONTROLLERS, POWER SUPPLIES, NICs, HBAs, SFPs, Cables, etc.

READ ME

  • Some options may not be displayed until the compatible parent option is chosen ie. Chassis – Drives, Processor – RAM etc.
  • “Submit for Quote” items can be added to your cart and sent to us via the cart page
  • Click the blue bar to close/open a section from view after choosing your options

Select Chassis

Select Processor Series

If higher or lower speed DIMMs are selected than what is shown in the table for a given CPU, the DIMMs will be clocked at the lowest common denominator of CPU clock and DIMM clock.

E5-2600 v3 Series Processor Family CPU

E5-2600 v4 Series Processor Family CPU

Select Riser 1 (Optional)

The selection of riser card 1 determines the number and type of PCIe cards and SATA boot drives supported in the riser.

Select Riser 2 (Optional)

Select Memory

Power capping is not supported when using 64GB TSV-RDIMMS.
Look below for more information

Select Memory Mode (Optional)

When memory mirroring is enabled, the memory subsystem simultaneously writes identical data to two channels.

Select RAID Controller

View below for more details on the RAID Controllers

Select HDD (Optional)

You can choose only SAS HDDs when using the Cisco 12G SAS Modular RAID Controller or Cisco 12 Gbps Modular SAS HBA.

Select SSD (Optional)

A maximum of two of the 400 GB 3.5-inch hybrid enterprise performance 12G SSDs can be installed.

Select Boot Device (Optional)

If you order one or two boot drives, you can order a maximum of one GPU and it must be installed in Riser 2 (UCSC-PCI-2-C240M4) slot 5.

Select PCIe Option Card(s) (Optional)

The mLOM cards do not plug into any of the riser 1 or riser 2 card slots; instead, they plug into a connector inside the server chassis.

Select Network Card Accessories (Optional)

Choose Up to Two Twinax Cables for Each Network Card Ordered
Choose Up to Two SFP+ Modules for Each Network Card Ordered

Select GPU Card(s) (Optional)

Slot 5 on riser card 2 is the required slot for the first GPU.

Select Power Supplies

Select Power Cable(s)

You can select a minimum of no power cords and a maximum of two. If you select the option R2XX-DMYMPWRCORD, no power cord is shipped with the server.

Select Rail Kit

Select CMA (Optional)

The reversible cable management arm mounts on either the right or left slide rails at the rear of the server and is used for cable management.

Select NIC Mode (Optional)

By default, the C240 M4 server NIC mode is configured to be Shared LOM Extended.

Select Trusted Platform Module (TPM) (Optional)

Trusted Platform Module (TPM) is a computer chip (microcontroller) that can securely store artifacts used to authenticate the platform (server). T

Select Flash SD Card Module (Optional)

Install either one or two 64 GB SD cards or one or two 32 GB SD cards
Do Not Mix SD Cards

Select USB 3.0 Drive (Optional)

Select Warranty

Helpful Tip: Once desired configuration is selected click "Add to Cart". From the cart page you can submit a submit a quote request for best pricing

The UCS C240 M4 Large form factor (LFF) server is a 2U rack server from Cisco, designedfor both performance and expandability over a wide range of storage-intensive infrastructure workloadsfrom big data to collaboration.

The enterprise-class UCS C240 M4 LFF server extends the capabilities of Cisco’s Unified Computing Systemportfolio in a 2U form factor with the addition of the Intel® Xeon E5-2600 v3 and v4 series processor familythat delivers the best combination of performance, flexibility, and efficiency gains. In addition, the UCSC240 M4 LFF server provides 24 DIMM slots, up to 6 PCI Express (PCIe) 3.0 slots, up to 12 front-loading drivesplus two (optional) internal SATA boot drives for a total of 14 internal drives.

The C240 M4 server includes a modular LAN on motherboard (mLOM) slot for installation of a Cisco VirtualInterface Card (VIC) or third-party network interface card (NIC) without consuming a PCI slot in addition to2 x 1 GbE embedded (on the motherboard) LOM ports. These features combine to provide outstanding levelsof internal memory and storage expandability along with exceptional performance.

The Cisco UCS C240 M4 server can be used standalone, or as part of the Cisco Unified Computing System,which unifies computing, networking, management, virtualization, and storage access into a singleintegrated architecture enabling end-to-end server visibility, management, and control in both bare metaland virtualized environments.

 

Current Configuration

Select Chassis

None

Select Processor Series

None

Select Riser 1 (Optional)

None

Select Riser 2 (Optional)

None

Select Memory

None

Select Memory Mode (Optional)

None

Select RAID Controller

None

Select HDD (Optional)

None

Select SSD (Optional)

None

Select Boot Device (Optional)

None

Select PCIe Option Card(s) (Optional)

None

Select Network Card Accessories (Optional)

None

Select GPU Card(s) (Optional)

None

Select Power Supplies

None

Select Power Cable(s)

None

Select Rail Kit

None

Select CMA (Optional)

None

Select NIC Mode (Optional)

None

Select Trusted Platform Module (TPM) (Optional)

None

Select Flash SD Card Module (Optional)

None

Select USB 3.0 Drive (Optional)

None

Select Warranty

None
*list also serves as quick links to each section

Price as Configured: $0.00

Welcome to the Request Express Quoting Form!

for: Cisco UCS C240 C-Series M4 12x 3.5" LFF Rack Servers CTO


This streamlined form is designed to simplify the quoting process for you. Whether you're uncertain about specific parts or seeking a hassle-free experience, you're in the right place.

Provide us with the necessary details, and we'll generate a customized quote for your server. Even if you're unsure about the exact components you need, we've got you covered. Our team will tailor a solution based on the information you provide.

Let's get started!
Simply fill out the form, and we'll take care of the rest.


Name *
Email *
Message *
Preferred Brand
Form Factor
Rack Unit of Height (#U)
Processor(s)
Memory
Total Amount of Memory
Total Amount of Usable Storage

Storage Type


RAID

List Networking Connection needed:
Rack Space Restrictions
Which OS do you plan on using:


Add to Cart

Please select at least 1 item from the configuration list before adding to cart

Product Specs

Base Standard Capabilities

Capability / FeatureDescription
ChassisTwo rack unit (2RU) chassis
CPUOne or two Intel Xeon E5-2600 v3 or v4 series processor family CPUs
ChipsetIntel® C610 series chipset
Memory24 slots for registered ECC DIMMs (RDIMMs) or load-reduced DIMMs (LRDIMMs)
Multi-bit Error ProtectionThis server supports multi-bit error protection.
Expansion slotsUp to six PCIe slots (on two riser cards)
  • Riser 1 (PCIe slots 1, 2, and 3), controlled by CPU 1
    • Option A: Two slots available. Slot 1 = full height, 3/4 length, x8, NCSI 1 . Slot 2 = full height, full length, x16, NCSI, GPU capable. NCSI is supported on only one slot at a time.
    • Option B: Three slots available. Slot 1 = full height, 3/4 length, x8. Slot 2 = full height, full length, x8, NCSI. Slot 3 = full height, full length, x8.
    • Option C: Two slots available. Slot 1 = full height, 3/4 length, x8, NCSI. Slot 2 = full height, full length, x16, NCSI. In addition, the riser contains two connectors for connecting up to two SATA boot drives.
  • Riser 2 (PCIe slots 4, 5, and 6), controlled by CPU 2. Three slots available. Slot 4 = full height, 3/4 length, x8, NCSI. Slot 5 = full height, full length, x16, NCSI, GPU capable. Slot 6 = full height, full length, x8. NCSI is supported on only one slot at a time.
  • Dedicated RAID controller slot
    • An internal slot is reserved for the Cisco 12G SAS Modular RAID controller.
VideoThe Cisco Integrated Management Controller (CIMC) provides video using the Matrox G200e video/graphics controller:
  • Integrated 2D graphics core with hardware acceleration
  • DDR2/3 memory interface supports up to 512 MB of addressable memory (8 MB is allocated by default to video memory)
  • Supports display resolutions up to 1920 x 1200 16bpp @ 60Hz
  • High-speed integrated 24-bit RAMDAC
  • Single lane PCI-Express host interface running at Gen 1 speed
Internal storage devicesDrives are installed into front-panel drive bays that provide hot-pluggable access.
  • Large Form Factor (LFF) drives. The server can hold up to 12 3.5-inch SAS hard disk drives (HDDs). The server uses a 12-drive backplane with a SAS expander. Additionally, two optional internal 2.5 inch SATA SSDs can be installed for booting an OS.
  • The server also contains one internal USB 3.0 port on the motherboard that you can use with an optional 16 GB USB thumb drive for additional storage
  • UCS Storage Accelerators are also available. These PCIe plug-in flash storage cards provide independent high-speed storage.
Cisco Flexible Flash drivesThe server supports up to two internal 32 GB or two internal 64 GB Cisco Flexible Flash drives (SD cards).
The second SD card is blank and can be used to mirror the first SD card. It can be used to protect the Hypervisor Partition with RAID1.
Interfaces
  • Rear panel
    • One DB15 VGA connector
    • One RJ45 serial port connector
    • Two USB 3.0 port connectors
    • One RJ-45 10/100/1000 Ethernet management port, using Cisco Integrated Management Controller (CIMC) firmware
    • Two Intel i350 embedded (on the motherboard) GbE LOM ports
    • One flexible modular LAN on motherboard (mLOM) slot that can accommodate various interface cards
  • Various PCIe card ports (dependent on which cards are installed)
    • Virtual Interface Card (VIC) ports
    • Converged Network Adapter (CNA) ports
    • Network Interface Card (NIC) ports
    • Host Bus Adapter (HBA) ports
  • Front panel
    • One KVM console connector (supplies two USB 2.0 connectors, one VGA DB15 video connector, and one serial port (RS232) RJ45 connector)
Power subsystemUp to two of the following hot-swappable power supplies:
  • 650 W (AC)
  • 930 W (DC)
  • 1200 W (AC)
  • 1400 W (AC)
One power supply is mandatory; one more can be added for 1 + 1 redundancy.
Storage controller
Cisco 12G SAS Modular RAID controller card with internal SAS connectivity.
  • Supports up to 24 internal drives (note however that this server can be configured with a maximum of 12 drives)
  • Plugs into a dedicated RAID controller slot

Can be purchased alone, or along with an onboard Flash-Backed Write Cache (FBWC) upgrade option, as shown in the table below
Notes
RAID Card VersionSupported RAID LevelsOnboard FBWC
UCSC-MRAID12G [1]JBOD, 0, 1, 10None
UCSC-MRAID12G-1GB [2]JBOD, 0, 1, 10, 5, 6, 50, 601 GB
UCSC-MRAID12G-2GB [2]JBOD, 0, 1, 10, 5, 6, 50, 602 GB
UCSC-MRAID12G-4GB [2]JBOD, 0, 1, 10, 5, 6, 50, 604 GB
1. Base RAID controller card (RAID 0, 1, 10 only)
2. FBWC option for base RAID controller card (adding the FBWC option extends the RAID levels)

All versions of the UCSC-MRAID12G RAID controller support up to 24 internal SAS (limited to 12 drives for this server).

Cisco 12 Gbps Modular SAS HBA with internal SAS connectivity
  • Supports up to 24 internal drives (note however that this server can be configured with a maximum of 12 drives)
  • Plugs into a dedicated PCIe slot at the rear of the server (slot 1 of riser 1)
  • Supports JBOD only, not RAID, as shown in the below table.
HBA Card VersionSupported RAID Levels
UCSC-SAS12GHBAJBOD only


Cisco 9300-8E 12G SAS HBA with external SAS connectivity
  • Provides 8 external SAS ports
  • Plugs into a PCIe slot at the rear of the server
  • No FBWC (cache) or cache power backup
  • SAS 3.0 compliant
Embedded NICTwo embedded (on the motherboard) Intel i350 GbE ports, supporting the following:
  • Pre-Execution Boot (PXE boot)
  • iSCSI boot
  • Checksum and segmentation offload
  • NIC teaming
Modular LAN on Motherboard (mLOM) slotThe mLOM slot can flexibly accommodate the following cards:
  • Cisco Virtual Interface Cards (VIC)
  • Quad Port Intel i350 1GbE RJ45 Network Interface Card (NIC)
NOTE: The four Intel i350 ports are provided on an optional card that plugs into the mLOM slot, and are separate from the two embedded (on the motherboard) LAN ports
WoLThe 1-Gb Base-T Ethernet LAN ports support the wake-on-LAN (WoL) standard.
Front PanelA front panel controller provides status indications and control buttons
ACPIThis server supports the advanced configuration and power interface (ACPI) 4.0 standard.
FansChassis: 6 hot-swappable fans for front-to-rear cooling
Integrated management processorBaseboard Management Controller (BMC) running Cisco Integrated Management Controller (CIMC) firmware.

Depending on your CIMC settings, the CIMC can be accessed through the 1-GbE dedicated management port, the 1-GbE LOM ports, or a Cisco virtual interface card (VIC).
Boot drivesUp to two optional SATA drives can be installed internal to the chassis on riser 1. The two SATA boot drives are supported only on the 24-drive backplane chassis version and are managed in AHCI mode, using OS-based software RAID.
Footer
The four Intel i350 ports are provided on an optional card that plugs into the mLOM slot, and are separate from the two embedded (on the motherboard) LAN ports
NCSI = Network Communications Services Interface protocol. An NCSI slot is powered even when the server is in standby power mode.
The drives are available as both self-encrypted drives (SED) and non self-encrypted drives.

Available Riser Cards

Product ID (PID) PID Description
Riser 1 Options
UCSC-PCI-1A-240M4 C240 M4 PCIe Riser 1 Assy (option A) (2 PCIe slots: 1x8 and 1x16 GPU capable)
UCSC-PCI-1B-240M4 C240 M4 PCIe Riser 1 Assy (option B) (3 PCIe slots: 3x8)
UCSC-PCI-1C-240M4 C240 M4 PCIe Riser 1 Assy (option C) (2 PCIe slots: 1x8 and 1x16 plus connectors for 2 SATA boot drives)
Riser 2 Options
UCSC-PCI-2-C240M4PCIe Riser Board (Riser 2) for C240 M4 (3 slots: 2x8 and 1x16)
Footnote:
[1]Riser card 1 is the one on the left when viewed from the back of the server and riser card 2 is on the right.
[2]The selection of riser card 1 determines the number and type of PCIe cards and SATA boot drives supported in the riser.
[3]If no riser is selected, a riser blanking panel will be installed. You will not be able to install any PCIe cards without a riser selected

Available CPU's

Product ID (PID) Intel Number Clock Freq (GHz) Power (W) Cache Size (MB) Cores QPI Highest DDR4 DIMM Clock Support (MHz) [1]
E5-2600 v4 Series Processor Family CPUs
UCS-CPU-E52699E E5-2699 v4 2.2 145 55 22 9.6 GT/s 2400
UCS-CPU-E52698E E5-2698 v4 2.2 135 50 20 9.6 GT/s 2400
UCS-CPU-E52697AE E5-2697A v4 2.6 145 40 16 9.6 GT/s 2400
UCS-CPU-E52697E E5-2697 v4 2.3 145 45 18 9.6 GT/s 2400
UCS-CPU-E52695E E5-2695 v4 2.1 120 45 18 9.6 GT/s 2400
UCS-CPU-E52690E E5-2690 v4 2.6 135 35 14 9.6 GT/s 2400
UCS-CPU-E52683E E5-2683 v4 2.1 120 40 16 9.6 GT/s 2400
UCS-CPU-E52680E E5-2680 v4 2.4 120 35 14 9.6 GT/s 2400
UCS-CPU-E52667E E5-2667 v4 3.2 135 25 8 9.6 GT/s 2400
UCS-CPU-E52660E E5-2660 v4 2 105 35 14 9.6 GT/s 2400
UCS-CPU-E52650E E5-2650 v4 2.2 105 30 12 9.6 GT/s 2400
UCS-CPU-E52650LE E5-2650L v4 1.7 65 35 14 9.6 GT/s 2400
UCS-CPU-E52643E E5-2643 v4 3.4 135 20 6 9.6 GT/s 2400
UCS-CPU-E52640E E5-2640 v4 2.4 90 25 10 8 GT/s 2133
UCS-CPU-E52637E E5-2637 v4 3.5 135 15 4 9.6 GT/s 2400
UCS-CPU-E52630E E5-2630 v4 2.2 85 25 10 8 GT/s 2133
UCS-CPU-E52630LE E5-2630L v4 1.8 55 25 10 8 GT/s 2133
UCS-CPU-E52623E E5-2623 v4 2.6 85 10 4 8 GT/s 2133
UCS-CPU-E52620E E5-2620 v4 2.1 85 20 8 8 GT/s 2133
UCS-CPU-E52609E E5-2609 v4 1.7 85 20 8 6.4 GT/s 1866
UCS-CPU-E52658E E5-2658 v4 2.3 105 35 14 9.6 GT/s 2400
E5-2600 v3 Series Processor Family CPUs
UCS-CPU-E52699D E5-2699 v3 2.3 145 45 18 9.6 GT/s 2133
UCS-CPU-E52698D E5-2698 v3 2.3 135 40 16 9.6 GT/s 2133
UCS-CPU-E52697D E5-2697 v3 2.6 145 35 14 9.6 GT/s 2133
UCS-CPU-E52695D E5-2695 v3 2.3 120 35 14 9.6 GT/s 2133
UCS-CPU-E52690D E5-2690 v3 2.6 135 30 12 9.6 GT/s 2133
UCS-CPU-E52683D E5-2683 v3 2 120 35 14 9.6 GT/s 2133
UCS-CPU-E52680D E5-2680 v3 2.5 120 30 12 9.6 GT/s 2133
UCS-CPU-E52670D E5-2670 v3 2.3 120 30 12 9.6 GT/s 2133
UCS-CPU-E52667D E5-2667 v3 3.2 135 20 8 9.6 GT/s 2133
UCS-CPU-E52660D E5-2660 v3 2.6 105 25 10 9.6 GT/s 2133
UCS-CPU-E52658D E5-2658 v3 2.2 105 30 12 9.6 GT/s 2133
UCS-CPU-E52650D E5-2650 v3 2.3 105 25 10 9.6 GT/s 2133
UCS-CPU-E52650LD E5-2650L v3 1.8 65 30 12 9.6 GT/s 1866
UCS-CPU-E52643D E5-2643 v3 3.4 135 20 6 9.6 GT/s 2133
UCS-CPU-E52640D E5-2640 v3 2.6 90 20 8 8 GT/s 1866
UCS-CPU-E52637D E5-2637 v3 3.5 135 15 4 9.6 GT/s 2133
UCS-CPU-E52630D E5-2630 v3 2.4 85 20 8 8 GT/s 1866
UCS-CPU-E52630LD E5-2630L v3 1.8 55 20 8 8 GT/s 1866
UCS-CPU-E52623D E5-2623 v3 3 105 10 4 8 GT/s 1866
UCS-CPU-E52620D E5-2620 v3 2.4 85 15 6 8 GT/s 1866
UCS-CPU-E52609D [2] E5-2609 v3 1.9 85 15 6 6.4 GT/s 1600
Footnote:
[1]If higher or lower speed DIMMs are selected than what is shown in the table for a given CPU, the DIMMs will be clocked at the lowest common denominator of CPU clock and DIMM clock
[Caveats]-
[1]You can select either one processor or two identical processors.
[2]For optimal performance, select DIMMs with the highest clock speed for a given processor
[Specs]-
[1]Intel Xeon E5-2600 v3 and v4 series processor family CPUs
[2]Intel C610 series chipset
[3]Cache size of up to 55 MB

Available DIMMs and Memory Mirroring

Product ID (PID) PID Description Voltage Ranks /DIMM
2400-MHz DIMM Options
UCS-ML-1X644RV-A 64GB DDR4-2400-MHz LRDIMM/PC4-19200/quad rank/x4 1.2 V 4
UCS-MR-1X322RV-A 32GB DDR4-2400-MHz RDIMM/PC4-19200/dual rank/x4 1.2 V 2
UCS-MR-1X161RV-A 16GB DDR4-2400-MHz RDIMM/PC4-19200/single rank/x4 1.2 V 1
UCS-MR-1X081RV-A 8 GB DDR4-2400-MHz RDIMM/PC4-19200/single rank/x4 1.2 V 1
UCS-ML-1X324RV-A 32GB DDR4-2400-MHz LRDIMM/PC4-19200/quad rank/x4 1.2 V 4
UCS-MR-1X162RV-A 16GB DDR4-2400-MHz RDIMM/PC4-19200/dual rank/x4 1.2 V 2
2133-MHz DIMM Options
UCS-MR-1X648RU-A [1], [2] 64GB DDR4-2133-MHz TSV-RDIMM/PC4-17000/octal rank/x4 1.2 V 8
UCS-MR-1X322RU-A 32GB DDR4-2133-MHz RDIMM/PC4-17000/dual rank/x4 1.2 V 2
UCS-ML-1X324RU-A 32GB DDR4-2133-MHz LRDIMM/PC4-17000/quad rank/x4 1.2 V 4
UCS-MR-1X162RU-A 16GB DDR4-2133-MHz RDIMM/PC4-17000/dual rank/x4 1.2 V 2
UCS-MR-1X081RU-A 8GB DDR4-2133-MHz RDIMM/PC4-17000/single rank/x4 1.2 V 1
Memory Mirroring Option
N01-MMIRROR Memory mirroring option - -
Footnote:
[1]Power capping is not supported when using 64GB TSV-RDIMMS.
[2]NVIDIA GPUs can support only less than 1 TB of total memory in the server. Do not install more than fourteen 64-GB DIMMs when using an NVIDIA GPU card in this server.
[1-CPU]Without memory mirroring: Select from 1 to 12 DIMMs.
[2-CPU]Without memory mirroring: Select from 1 to 12 DIMMs.
[1]System performance is optimized when the DIMM type and quantity are equal for both CPUs, and when all channels are filled equally across the CPUs in the server.
[2]System speed is dependent on how many DIMMs are populated per channel and the CPU DIMM speed support.
[3]When you mix 2400 MHz RDIMMs of different sizes (for example, 4x32GB + 4x16GB), the memory speed clocks one step down to 2133 MHz.
[4]Do not mix RDIMMs with LRDIMMs
[5]Do not mix 64GB DDR4-2133-MHz TSV-RDIMMs with any other DIMMs
[6]Single-rank DIMMs can be mixed with dual-rank DIMMs in the same channel
[7]Do not mix quad-rank DIMMs with single- or dual-rank DIMMs in the same channel
[8]DIMMs for CPU 1 and CPU 2 (when populated) must always be configured identically.
[9]When using mirroring, DIMMs must be installed in identical pairs across paired DDR4 buses. That is, mirrored pairs in channels A and B must be identical and pairs in channels C and D must be identical. However, the DIMMs used in channels A and B can be different from those in channels C and D.
[10]Memory mirroring reduces the amount of available memory by 50% (quantity of DIMMs must be even for mirroring).
[11]Non-ECC DIMMs are not supported.
[12]Cisco memory from previous generation servers (DDR3) is not compatible with this server

Available RAID Controllers

Product ID (PID) PID Description
Controllers for Internal Drives
-Note that if the following Cisco 12G SAS Modular RAID controller or Cisco 12Gbps Modular SAS HBA controller is selected, it is factory-installed in the dedicated internal slot.
UCSC-MRAID12GCisco 12G SAS Modular RAID Controller
  • Supports up to 24 internal SAS HDDs and SAS/SATA SSDs (limited to 12 drives in this server)
  • Supports JBOD, RAID 0, 1, 10 (with no FBWC option chosen) and has the ability to also support RAID 5, 6 if a Flash-Backed Write cache upgrade is chosen (shown below in this table)
UCSC-SAS12GHBACisco 12 Gbps Modular SAS HBA
  • Supports up to 24 internal SAS HDDs and SAS/SATA SSDs (limited to 12 drives in this server)
  • Supports JBOD mode only (no RAID functionality. Ideal for SDS (Software Defined Storage) applications. It is also ideal for environments demanding the highest IOPs (for external SSD attach), where a RAID controller can be an I/O bottleneck.
UCSC-PSAS12GHBASame functionality as UCSC-SAS12GHBA, but vendor is Microsemi
Flash-Backed Write Cache (FBWC) Upgrade Options for Cisco 12G SAS Modular RAID controller
UCSC-MRAID12G-1GB1 GB FBWC, which includes a 1 GB MB memory plus a SuperCap for write cache backup. Supports JBOD, RAID 0, 1, 10, 5, 6, 50, and 60.
UCSC-MRAID12G-2GB2 GB FBWC, which includes a 2 GB MB memory plus a SuperCap for write cache backup. Supports JBOD, RAID 0, 1, 10, 5, 6, 50, and 60.
UCSC-MRAID12G-4GB4 GB FBWC, which includes a 4 GB MB memory plus a SuperCap for write cache backup. Supports JBOD, RAID 0, 1, 10, 5, 6, 50, and 60.
SAS HBA for External JBOD Attach
Two SFF8644 mini-SAS HD connectors on this card are accessible at the rear of the chassis.
UCSC-SAS9300-8ECisco 9300-8e 12G SAS HBA for external JBOD attach
Supports external JBOD using X8 wide SAS ports.
RAID Configuration Options (not available for Cisco 12 Gbps Modular SAS HBA or embedded software RAID)
R2XX-SRAID0Enable Single Disk Raid 0 Setting
R2XX-RAID0Factory preconfigured RAID striping option Enable RAID 0 Setting. Requires a minimum of one hard drive.
R2XX-RAID1Factory preconfigured RAID mirroring option Enable RAID 1 Setting. Requires exactly two drives with the same size, speed, capacity.
R2XX-RAID5Factory preconfigured RAID option Enable RAID 5 Setting. Requires a minimum of three drives of the same size, speed, capacity.
R2XX-RAID6Factory preconfigured RAID option Enable RAID 6 Setting. Requires a minimum of four drives of the same size, speed, capacity.
Footnote:
[Caveats]-
[1]A maximum of one Cisco 9300-8e 12G SAS HBA can be installed, and it can be installed in any slot (depending on the number of CPUs installed). The system can also support combinations of one Cisco 9300-8e 12G SAS HBA and a Storage Accelerator card along with either a Cisco 12G SAS Modular RAID Controller, or a Cisco 12 Gbps Modular SAS HBA
[2]For the Cisco 12G SAS Modular RAID controller, you can choose an optional RAID configuration (up to RAID 0, 1, 10, 5, 6, 50, 60 if optional FBWC option is chosen), which is preconfigured at the factory. The RAID level you choose must be an available RAID choice for the controller selected. RAID levels 50 and 60 are supported, although they are not available as configuration options. It can also be combined with AHCI support for internal SSDs (SATA Boot Drives).
[Approved Configurations]-
[1]The Cisco 12G SAS Modular RAID controller option supports up to 12 internal SAS HDDs with up to RAID 0, 1, 10, 5, 6, 50, 60 support (with FBWC option chosen).
[2]The Cisco 12 Gbps Modular SAS HBA option supports up to 12 internal SAS HDDs with JBOD support.
[3]The Cisco 9300-8e 12G SAS HBA supports up to 8 external SAS ports with JBOD support.
[SAS HBA (internal HDD/SSD/JBOD support)]-
[-]Instead of a RAID controller, you can choose a SAS HBA for internal drive connectivity (non-RAID):

Cisco 12 Gbps Modular SAS HBA, which plugs into a dedicated RAID controller slot.
[SAS HBA (external JBOD support)]-
[-]In addition to a RAID controller or JBOD SAS HBA for internal drives, you can choose the following SAS HBA for external drive connectivity (non-RAID):

Cisco 9300-8e 12G SAS HBA (provides 8 SAS ports for external JBOD connectivity).
[RAID Volumes and Groups]-
[]When creating each RAID volume, follow these guidelines:
  • Use the same capacity for each drive in each RAID volume
  • For the Cisco 12G SAS modular RAID controller upgrade:
    — Use all SAS HDDs in each RAID volume
  • The number of RAID groups (virtual drives) supported per RAID controller is as follows:
    Cisco 12G SAS Modular RAID controller = 64
  • Cisco 12G SAS modular RAID controller or Cisco 12 Gbps Modular SAS HBA
  • Mixed controllers:
    -One Cisco 12G SAS modular RAID controller or Cisco 12 Gbps Modular SAS HBA and
    -One or two Cisco 9300-8E 12G SAS HBAs for external SAS JBOD/enclosure connectivity support
  • Dual HBAs:
    -Two Cisco 9300-8E 12G SAS HBAs (JBOD support only for external drives
NOTES:Mixing the Cisco 9300-8E 12G SAS HBA in the same server as the Cisco 12 Gbps Modular SAS HBA requires the following firmware levels:
  • Cisco IMC/BIOS 2.0(8) or later
  • Cisco UCS Manager 2.2(6) or later (for integrated servers only)
NOTES:The Cisco 12G SAS modular RAID controller can be ordered with or without an optional FBWC. The FBWC option backs up the RAID controller write cache. The FBWC is available in 1 GB, 2 GB, or 4 GB sizes.

Available 3.5"" LFF Hot-pluggable Drives

Product ID (PID) PID Description Drive Type Capacity
HDDs
UCS-HD600G15CK9 600 GB 12G SAS 15K RPM LFF HDD (SED) SAS 600 GB
UCS-HD6T12GAK9 6 TB 7.2K RPM HDD (4K sector format, SED) SAS 6 TB
UCS-HD4T12GK9 4 TB 7.2K RPM HDD (SED) SAS 4 TB
UCS-HD10T7KL4K [2] 10 TB 12G SAS 7.2K RPM LFF HDD (4K sector format) SAS 10 TB
UCS-HD10T7KEM 10 TB 12G SAS 7.2K RPM LFF HDD (512e) SAS 10 TB
UCS-HD8T7KEM 8 TB 12G SAS 7.2K RPM LFF HDD (512e) SAS 8 TB
UCS-HD6T7KEM 6 TB 12G SAS 7.2K RPM LFF HDD (512e) SAS 6 TB
UCS-HD1T7KL12G 1 TB 12G SAS 7.2K RPM LFF HDD SAS 6 TB
UCS-HD4T7KL12G 4 TB 12G SAS 7.2K RPM LFF HDD SAS 4 TB
UCS-HD2T7KL12G 2 TB 12G SAS 7.2K RPM LFF HDD SAS 2 TB
UCS-HD8T7KL4K [2] 8 TB 12G SAS 7.2K RPM LFF HDD (4K sector format) SAS 8 TB
UCS-HD6T7KL4K [2] 6 TB 12G SAS 7.2K RPM LFF HDD (4K sector format) SAS 6 TB
UCS-HD4T7KL4K [2] 4 TB 12G SAS 7.2K RPM LFF HDD (4K sector format) SAS 4 TB
UCS-HD2T7KL4K [2] 2 TB 12G SAS 7.2K RPM LFF HDD (4K sector format) SAS 2 TB
UCS-HD12TB10KHY-E 1.2 TB 3.5 inch 12G SAS 10K RPM HDD SAS 1.2 TB
UCS-HDD1TI2F212 1 TB SAS 7.2K RPM LFF HDD SAS 1 TB
UCS-HD600G15KHY-E 600 GB 3.5 inch Hybrid 6G SAS 15K RPM HDD SAS 600 GB
UCS-HD300G15KHY-E 300 GB 3.5 inch Hybrid 6G SAS 15K RPM HDD SAS 300 GB
SSDs
UCS-SD800GBCK9 800 GB 2.5"" Enterprise performance SAS SSD (10X FWPD-SED) SAS 800 GB
UCS-SD400GBCK9 400 GB 2.5"" Enterprise performance SAS SSD (10X FWPF-SED) SAS 400 GB
UCS-SD16TG0KHY-EP 1.6 TB 3.5 inch Enterprise performance 6G SATA SSD (3X FWPD, Intel 3610) SATA 1.6 TB
UCS-SD800G0KHY-EP 800 GB 3.5 inch Hybrid Enterprise Performance 12G SSD (10X FWPD, Samsung 1635) SAS 800 GB
UCS-SD480G0KHY-EP 480 GB 3.5 inch Enterprise Performance 6G SATA SSD (3X FWPD, Intel 3610) SATA 480 GB
UCS-SD120G0KHY-EV 120 GB 3.5 inch Enterprise Performance 6G SATA SSD (1FWPD) SATA 120 GB
Boot Drives
UCS-SD120GBE1K9 120GB Enterprise Value SSD (SATA) (1X FWPD, SED) (boot) SATA 120 GB
UCS-SD16TBKS4-EB 1.6 TB 2.5 inch Enterprise Value 6G SATA SSD (BOOT) SATA 1.6 TB
UCS-SD960G0KSB-EV 960 GB 2.5 inch Enterprise Value 6G SATA SSD (BOOT) SATA 960 GB
UCS-SD480G0KSB-EV 480 GB 2.5 inch Enterprise Value 6G SATA SSD (BOOT) SATA 480 GB
UCS-SD480GBKS4-EB 480 GB 2.5 inch Enterprise Value 6G SATA SSD (Boot) SATA 480 GB
UCS-SD240GBKS4-EB 240 GB 2.5 inch Enterprise Value 6G SATA SSD (boot) SATA 240 GB
UCS-SD120GBKS4-EB 120 GB 2.5 inch Enterprise Value 6G SATA SSD (boot) SATA 120 GB
UCS-SD120G0KSB-EV 120 GB 2.5 inch Enterprise Value 6G SATA SSD (BOOT) SATA 120 GB
Footnote:
[Notes]-
[1]For all self-encrypting drives (SED), standalone Management (CIMC) is supported for configuring and managing local keys (UCSM is not supported). Also, 4K format drives do not support Vmware and require UEFI boot.
[2]UCS Rack Servers require minimum firmware version 2.0(4) to support 4K sector size drives.
[3]EFI Mode must be used when booting from 4K sector size drives, legacy mode is not supported. Ensure that 4K sector size and 512 byte sector size drives are not mixed in the same RAID volume.
[Approved Configurations]-
[1]Cisco 12G SAS Modular RAID Controller
  • f you selected a Cisco 12G SAS Modular RAID controller you have the following options:
    • — Cisco 12G SAS Modular RAID controller with no FBWC option (supports JBOD, RAID 0, 1, 10)
    • — Cisco 12G SAS Modular RAID controller with FBWC option (supports JBOD, RAID 0, 1, 10, 5, 6, 50, and 60)
    • — For either option, select up to 12 SAS HDDs listed in Table 11 on page 31. The Cisco 12G SAS Modular RAID controller does not support SATA HDDs.
[2]Cisco 12 Gbps Modular SAS HBA
If you selected a Cisco 12 Gbps Modular SAS HBA, select up to 12 SAS HDDs.
[3]Systems Using Boot Drives
f you are configuring a system that uses SATA SSD boot drives, choose up to two identical boot drives
[Caveats]-
[1]You can choose only SAS HDDs when using the Cisco 12G SAS Modular RAID Controller or Cisco 12 Gbps Modular SAS HBA.
[2]If you order one or two boot drives, you can order a maximum of one GPU and it must be installed in Riser 2 (UCSC-PCI-2-C240M4) slot 5.
[3]A maximum of two of the 400 GB 3.5-inch hybrid enterprise performance 12G SSDs can be installed.

Available PCIe Option Cards

Product ID (PID) PID Description Card Height
Modular LAN on Motherboard (mLOM)
UCSC-MLOM-C10T-02 Cisco UCS VIC1227T VIC MLOM - Dual Port 10GBaseT N/A
UCSC-MLOM-CSC-02 Cisco UCS VIC1227 VIC MLOM - Dual Port 10Gb SFP+ N/A
UCSC-MLOM-IRJ45 Intel i350 quad-port MLOM NIC N/A
UCSC-MLOM-C40Q-03 Cisco VIC 1387 Dual Port 40Gb QSFP CNA MLOM N/A
Virtual Interface Cards (VICs)
UCSC-PCIE-CSC-02 Cisco VIC 1225 Dual Port 10Gb SFP+ CNA Half
UCSC-PCIE-C10T-02 Cisco VIC 1225T Dual Port 10GBaseT CNA Half
UCSC-PCIE-C40Q-03 Cisco VIC 1385 Dual Port 40Gb QSFP+ CNA w/RDMA Half
Network Interface Cards (NICs)
1 Gb NICs
N2XX-ABPCI03-M3 Broadcom 5709 Quad Port 1Gb w/TOE iSCSI for M3 Servers Half
N2XX-ABPCI01-M3 Broadcom 5709 Dual-Port Ethernet PCIe Adapter M3 & later Half
UCSC-PCIE-IRJ45 Intel i350 Quad Port 1Gb Adapter Half
10 Gb NICs
N2XX-AIPCI01 Intel X520 Dual Port 10Gb SFP+ Adapter Half
UCSC-PCIE-ITG Intel X540 Dual Port 10GBase-T Adapter Half
UCSC-PCIE-QNICBT QLogic QLE8442 dual-port 10Gbase-T NIC Half
UCSC-PCIE-QNICSFP QLogic QLE8442 dual-port 10G SFP+ NIC Half
UCSC-PCIE-ID10GC Intel X550-T2 dual-port 10GBase-T NIC Half
UCSC-PCIE-ID10GF Intel X710-DA2 dual-port 10G SFP+ NIC Half
UCSC-PCIE-IQ10GF Intel X710 quad-port 10G SFP+ NIC Half
UCSC-PCIE-ID40GF Intel XL710 dual-port 40G QSFP+ NIC Half
10 Gb Converged Network Adapters (CNAs)
UCSC-PCIE-E14102B Emulex OCe14102B-UX dual-port 10G SFP+ with iSCSI, FCoE CNA Half
UCSC-PCIE-E14102 Emulex OCe14102-UX dual-port 10 GbE FCoE CNA Half
UCSC-PCIE-Q8362 Qlogic QLE8362 dual-port 10 GbE FCoE CNA Half
Host Bus Adapters (HBAs)
N2XX-AQPCI05 Qlogic QLE2562 Dual Port 8Gb Fibre Channel HBA Half
UCSC-PCIE-Q2672 Qlogic QLE2672-CSC, 16Gb Fibre Channel HBA with SR Optics N2XX-AEPCI05 Emulex LPe 12002 Dual Port 8Gb Fibre Channel HBA Half
N2XX-AEPCI05 Emulex LPe 12002 Dual Port 8Gb Fibre Channel HBA Half
UCSC-PCIE-E16002 Emulex LPe16002-M6, 16Gb Fibre Channel HBA with SR Optics Half
UCS Storage Accelerators [3]
UCSC-F-S13002 UCS Rack PCIe Storage 1300 GB SanDisk SX350 Medium Endurance Half
UCSC-F-S16002 UCS Rack PCIe Storage 1600 GB SanDisk SX350 Medium Endurance Half
UCSC-F-S32002 UCS Rack PCIe Storage 3200 GB SanDisk SX350 Medium Endurance Half
UCSC-F-S64002 UCS Rack PCIe Storage 6400 GB SanDisk SX350 Medium Endurance Full
UCSC-F-FIO-5200PS UCS 5200 GB Fusion ioMemory3 PX Performance line for C-Series Full
UCSC-F-FIO-2600PS UCS 2600 GB Fusion ioMemory3 PX Performance line for C-Series Half
UCSC-F-FIO-1300PS UCS 1300 GB Fusion ioMemory3 PX Performance line for C-Series Half
UCSC-F-FIO-1000PS UCS 1000 GB Fusion ioMemory3 PX Performance line for C-Series Half
UCS NVMe/PCie Add in Cards
UCSC-F-H38001 3.8 TB NVMe/PCIe storage (HGST SN150) Read Intensive Half
UCSC-F-I20003 2.0 TB NVMe/PCIe storage (Intel P3600) High Endurance Half
UCSC-F-H19001 1.9 GB NVMe/PCIe storage (HGST SN150) Read Intensive Half
UCSC-F-I160010 1.6 TB NVMe/PCIe storage (Intel P3700) High Endurance Half
UCSC-F-I12003 1.2 GB NVMe/PCIe storage (Intel P3600) High Endurance Half
UCSC-F-I80010 800 GB NVMe/PCIe storage (Intel P3700) High Endurance Half
Footnote:
[1]The GPU cards must be inserted into a full length x16 (electrical) PCIe slot. The rest of the PCIe cards are x8 (electrical) and can be plugged into any PCIe slot of riser 1 or riser 2.
[2]The mLOM cards do not plug into any of the riser 1 or riser 2 card slots
[4]A maximum of six storage accelerator cards are supported and some are riser dependent. 1.3 TB, 2.6 TB, or 3.2 TB cards should not be installed in slots 5 or 6 so the total number of those capacity points is four. The Cisco 9300-8e 12G SAS HBA also can only be installed in riser 1
[Caveats]-
[-]If you choose an external drives controller (Cisco 9300-8e 12G SAS HBA), it will consume one PCIe slot.
[-]A maximum of six storage accelerator cards are supported and some are riser dependent. 1.3 TB, 2.6 TB, or 3.2 TB cards should not be installed in to slots 5 or 6 so the total number of those capacity points is four.
[For 1-CPU systems:]Only the PCIe slots on PCIe riser 1 are available for 1-CPU system.
[-]The PCIe slots on riser 2 are not supported on 1-CPU systems. The slots are full-height PCIe slots 4, 5, and 6
[-]Only a single plug-in PCIe VIC card may be installed on a 1-CPU system, and it must be installed in slot 2 of riser 1. You can order an mLOM VIC card to be installed in the mLOM slot internal to the chassis and thus have two VIC cards in operation at the same time.
[For 2-CPU systems:]Depending on the riser 1 option chosen, up to six PCIe slots are available, three on PCIe riser 1 (PCIe slots 1, 2, and 3) and three on PCIe riser 2 (PCIe slots 4, 5, and 6).
[-]All of the slots are full-height.
[-]Two plug-in PCIe VIC cards can be installed in 2-CPU systems, using slots 2 and 5. In addition, you can order an mLOM VIC card, which is installed in the mLOM slot inside the chassis and thus have three VIC cards in operation at the same time.
[-]If GPUs are installed in slots 2 (Riser 1 option A) and 5 (Riser 2), the NCSI capability automatically switches over to slots 1 (Riser 1 option A) and 4 (Riser 2). Therefore, Cisco PCIe VICs can be installed in slots 1 and 4 if GPUs are installed in slots 2 and 5.
[Notes]UCSM managed servers are discoverable only if a VIC 1225 is installed in slot 2 or a VIC 1227/1227T is installed in the MLOM slot. If you install two GPUs, they must be located in slots 2 and 5. Therefore, if two GPUs are installed, UCSM managed servers are discoverable only if you install a VIC 1227/1227T in the MLOM slot.
[-]The quantity and type of PCIe cards that can be installed depends in the riser card options.

Available Network Card Accessories (Optional)

Product ID(PID) PID Description
Available Twinax Cables
SFP-H10GB-CU1M10GBASE-CU SFP+ Cable (1 M)
SFP-H10GB-CU3M10GBASE-CU SFP+ Cable (3 M)
SFP-H10GB-CU5M10GBASE-CU SFP+ Cable (5 M)
SFP-H10GB-ACU7M10GBASE-CU SFP+ Cable (7 M)
SFP-H10GB-ACU10M10GBASE-CU SFP+ Cable (10 M)
Available SFP Modules
SFP-10G-SR10GBASE-SR SFP+ Module 850 nm, multimode, SR, 3.3V, LC connector, with Digital Optical Monitoring
SFP-10G-LR10GBASE-LR SFP+ Module 1310 nm, single mode, LR, 3.3 V, with Digital Optical Monitoring
DS-SFP-FC8G-SW8 Gbit SFP+ Module 850 nm, multimode, SR, 3.3V, LC connector, with Digital Optical Monitoring
Footnote:
[Approved Configurations]-
[1]Choose Up to Two Twinax Cables for Each Network Card Ordered
You may choose one or two twinax cables for each compatible PCIe network card ordered. The cables can be different lengths
[2]Choose Up to Two SFP+ Modules for Each Network Card Ordered
You may choose one or two SFP+ optical modules cables for each compatible PCIe network card ordered. You would normally order two modules for connecting to the primary and redundant network switching equipment. With the SFP+ optical modules, you can use common fiber optic cables, widely available.

GPU Cards (Optional)

Product ID (PID) PID Description Card Size
GPU PCIe Cards
UCSC-GPU-VGXK1 NVIDIA GRID K1 Full-Height, double wide -
UCSC-GPU-VGXK2 NVIDIA GRID K2 Full-Height, double wide -
UCSC-GPU-K40 NVIDIA Tesla K40 Full-Height, double wide -
UCSC-GPU-M60 [1] NVIDIA Tesla M60 Full-Height, double wide -
UCSC-GPU-K80 [1] NVIDIA K80 Full-Height, double wide -
Available GPU Power Cables
UCSC-GPUCBL-240M4 C240 M4 GPU Power Cable - -
Available GPU Power Cables (K80 and M60 only)
UCS-300WKIT-240M4 300 Watt Cable, HS and Kit for UCS C240M4 Rack Server - -
UCSC-C240-M4-LFF_GPU
Footnote:
[1]You must order a kit with this GPU (UCS-300WKIT-240M4). It is a 300-Watt cable, HS and kit system for the UCS C240M4 rack server. Only one kit is needed for either one or two GPUs.
[2]A power cable is not included with the M10. When ordering an M10, you must to purchase a power cable (UCSC-GPUCBL-240M4=) for the GPU.
[3]CAUTION: Do not operate the C240 M4 server with the 300W GPU kit installed, but no GPU card installed. The kit has been designed to provide adequate airflow for cooling only when at least one GPU card is installed.
[4]CAUTION: When using GPU cards, the operating temperature range is 32° to 95°F (0° to 35°C).
[5]All GPU cards require two CPUs and a minimum of two power supplies in the server. 1400 W power supplies are recommended. Use the power calculator at the following link to determine the needed power based on the options chosen (CPUs, drives, memory, and so on):
[6]Whenever you select a K1/K2/K40 or AMD GPU for this server, you must also select one power cable for each GPU selected.
[7]Whenever you select a K80 GPU for this server, you must also select one power cable kit (for either one or two K80 GPUs).
[Caveats]-
[-]NVIDIA GPUs can support only less than 1 TB of total memory in the server. Do not install more than fourteen 64-GB DIMMs when using an NVIDIA GPU card in this server. Please note, this limitation does not apply to Pascal series GPU (P100)
[-]NVIDIA GRID K1 and K2 GPUs can be mixed. No other GPU mixing is allowed.
[-]If you order a K80 GPU, note the following:
  • You cannot mix the K80 with any other GPU
  • You must select 2 CPUs for the server
[-]Slot 5 on riser card 2 is the required slot for the first GPU.
[-]Slot 2 on riser card 1 is the secondary slot for a second GPU. The riser card 1 options that are compatible with GPUs are:
  • Riser card 1 option A (UCSC-PCI-1A-240M4)
[-]If you order one or two boot drives, you can order a maximum of one GPU and it must be installed in Riser 2 (UCSC-PCI-2-C240M4) slot 5.

Available Power Supply

Product ID (PID) PID Description
UCSC-PSU2V2-1400W1400W V2 AC Power Supply (200 - 240V) 2U & 4U C Series
UCSC-PSU2V2-1200W [1]1200W / 800W V2 AC Power Supply for 2U C-Series Servers
UCSC-PSU-930WDC930 W -48V DC Common Slot Power Supply for C-series servers
UCSC-PSU2V2-930DC930 W - 48V V2 DC Power Supply for 2U C-Series Servers
UCSC-PSU2V2-650W650W V2 AC Power Supply for C-Series Servers
Footnote:
[1]The C240 M4 server requires at least one power supply. A lightly loaded server may require one or two 650 W power supplies. A fully loaded server might need to be powered with two larger capacity power supplies. A server with one GPU requires at least two power supplies (1400 W power supplies are recommended). A server with two GPUs also requires at least two power supplies (1400 W power supplies are recommended
[2]In a two power supply server, both power supplies must be identical

Available Power Cords

Product ID (PID) PID Description
R2XX-DMYMPWRCORDNo power cord (dummy PID to allow for a no power cord option)
CAB-N5K6A-NAPower Cord, 200/240V 6A, North America
CAB-AC-L620-C13AC Power Cord, NEMA L6-20 - C13, 2M/6.5ft
CAB-C13-CBNCABASY,WIRE,JUMPER CORD, 27"" L, C13/C14, 10A/250V
CAB-C13-C14-2MCABASY,WIRE,JUMPER CORD, PWR, 2 Meter, C13/C14,10A/250V
CAB-C13-C14-ACCORD,PWR,JMP,IEC60320/C14,IEC6 0320/C13, 3.0M
CAB-250V-10A-ARPower Cord, 250V, 10A, Argentina 186571 2500 mm Cordset rating: 10 A, 250/500 V MAX Length: 8.2 ft Plug: EL 219 (IRAM 2073) Connector: EL 701 (IEC60320/C13)
CAB-9K10A-AUPower Cord, 250VAC 10A 3112 Plug, Australia Plug: Cordset rating: 10 A, 250 V/500 V MAX Length: 2500mm 186580 Connector: EL 701C EL 210 (EN 60320/C15) (BS 1363A) 13 AMP fuse
CAB-250V-10A-CNAC Power Cord - 250V, 10A - PRC
CAB-9K10A-EUPower Cord, 250VAC 10A CEE 7/7 Plug, EU Connector: VSCC15 Cordset rating: 10A/16 A, 250 V Length: 8 ft 2 in. (2.5 m) Plug: M2511 186576
CAB-250V-10A-IDPower Cord, SFS, 250V, 10A, India
CAB-250V-10A-ISPower Cord, SFS, 250V, 10A, Israel
CAB-9K10A-ITPower Cord, 250VAC 10A CEI 23-16/VII Plug, Italy Plug: I/3G (CEI 23-16) Connector C15M (EN60320/C15 ) Cordset rating: 10 A, 250 V Length: 8 ft 2 in. (2.5 m) 186575
CAB-9K10A-SWPower Cord, 250VAC 10A MP232 Plug, Switzerland Plug: MP232-R Cordset rating: 10 A, 250 V Length: 8 ft. 2 in (2.5 m) 186578 Connector: IEC 60320 C15
CAB-9K10A-UKPower Cord, 250VAC 10A BS1363 Plug (13 A fuse), UK
CAB-9K12A-NAPower Cord, 125VAC 13A NEMA 5-15 Plug, North America
CAB-250V-10A-BRPower Cord - 250V, 10A - Brazil
CAB-48DC-40A-8AWGC-Series -48VDC PSU Power Cord, 3.5M, 3 Wire, 8AWG, 40A
CAB-C19-C20-3M-JPPower Cord C19-C20, 3M/10ft Japan PSE mark

Available Cable Management Arms (CMA)

Product ID (PID) PID Description
UCSC-CMAF-M4Reversible Cable Management Arm (CMA) for C220 M4 and M5 rack servers
Footnote:
[Notes]For more information about the tool-less rail kit and cable management arm, see the Cisco UCS C220 M5 Installation and Service Guide at this URL

Available NIC Mode (Optional)

Product ID (PID) PID Description
UCSC-DLOM-01Dedicated Mode BIOS setting for C-Series Servers
UCSC-CCARD-01Cisco Card Mode BIOS setting for C-Series Servers
Footnote:
[1]By default, the C220 M4 server NIC mode is configured to be Shared LOM Extended. This NIC mode allows any LOM port or adapter card port to be used to access the Cisco Integrated Management Controller (CIMC). The Cisco VIC card must be installed in a slot with NCSI support.
[2]To change the default NIC mode to Dedicated, select the UCSC-DLOM-01 PID shown in Table Above. In Dedicated NIC mode, the CIMC can be accessed only through the dedicated management port.
[3]To change the default NIC mode to Cisco Card Mode, select the UCSC-CCARD-01 PID shown in Table Above. In this mode, you can assign an IP address to the CIMC using DHCP and from there you can fully automate your deployment.

Available Security Devices (Optional)

Product ID (PID) PID Description
UCSX-TPM2-001Trusted Platform Module 1.2 SPI-based for UCS Servers
UCSX-TPM2-002Trusted Platform Module 2.0 for UCS servers
Footnote:
[1]A Trusted Platform Module (TPM) is a computer chip (microcontroller) that can securely store artifacts used to authenticate the platform (server). These artifacts can include passwords, certificates, or encryption keys. A TPM can also be used to store platform measurements that help ensure that the platform remains trustworthy. Authentication (ensuring that the platform can prove that it is what it claims to be) and attestation (a process helping to prove that a platform is trustworthy and has not been breached) are necessary steps to ensure safer computing in all environments.
[2]A chassis intrusion switch gives a notification of any unauthorized mechanical access into the server.
[Notes]The TPM module used in this system conforms to TPM v1.2 and 2.0, as defined by the Trusted Computing Group (TCG). It is also SPI-based.
[1]TPM installation is supported after-factory. However, a TPM installs with a one-way screw and cannot be replaced, upgraded, or moved to another server. If a server with a TPM is returned, the replacement server must be ordered with a new TPM.

Cisco SD Card Module (Optional)

Product ID (PID) PID Description
UCS-SD-64G-S64 GB SD Card for UCS Servers
UCS-SD-32G-S32 GB SD Card for UCS Servers
Footnote:
[Caveats]-
[1]Install either one or two SD cards
[2]Do not mix SD card sizes

Spare Parts List

Product ID (PID) PID Description
UCSC-PCIF-01F=PCIe Full Height blanking panel for UCS C-Series Server1
UCSC-PCIF-C240M4=C240 M4 PCIe Riser Blanking Panel1
UCSC-PCI-2-C240M4=C240 M4 PCIe Riser 2 Assembly1
UCSC-PCI-1A-240M4=C240 M4 PCIe Riser 1 Assembly (x8 slot + GPU)1
UCSC-PCI-1B-240M4=C240 M4 PCIe Riser 1 Assembly (3 x8 slots)1
UCSC-PCI-1C-240M4=C240 M4 PCIe Riser 1 Assembly (SATA Boot + 2 PCIe slots)1
UCSC-IP-PCH-240M4=Interposer board + cables for onboard PCH SATA 6G Embedded Software RAID1
UCSC-MLOM-BLK=MLOM Blanking Panel
UCS-240CBLMR12=C240 M4 set of 2 cables for 12 HDD backplane chassis2
UCSC-HS-C240M4=Heat Sink for UCS C240 M4 Rack Server1
UCS-CPU-LPCVR=CPU load plate dust cover (for unpopulated CPU sockets)
UCS-GPUCBL-240M4=C240 M4 GPU Power Cable (1 cable per GPU card)1
N20-MBLIBATT=Replacement Lithium Battery for Server Motherboard (CR2032)1
UCSC-FAN-C240M4=C240 M4 Fan Module (one)
UCSC-BAFF-C240M4=C240 M4 Air Baffle Replacement Kit
UCSC-PSU-BLKP240=Power Supply Blanking Panel for C240 M4 Servers1
UCSC-RAILB-M4=Tool-Less Ball Bearing Rail Kit for C220 M4 and C240 M4 rack servers
UCSC-CMAB-M4=Reversible CMA for C240 M4 ball bearing rail kit
UCS-SD-32G-S=32 GB SD Card for UCS servers3
UCS-SD-64G-S=64 GB SD Card for UCS servers2
UCS-USBFLSHB-16GB=16GB Flash USB Drive
N20-BKVM=KVM local IO cable for UCS servers console port
UCS-CPU-GREASE3=M4 Server CPU thermal grease syringe - needed for heatsink seal4
UCSX-HSCK=UCS Processor Heat Sink Cleaning Kit (when replacing a CPU)3
UCSC-MRAID-SC=SuperCap for Cisco 12G SAS Modular RAID, including all cables.
UCS-300WKIT-240M4=300 Watt Cable and Kit for UCS C240M4 Rack Server Includes two heat sinks and
Footnote:
[1]This part is included/configured with your UCS server (in some cases, as determined by the configuration of
[2]Required if ordering the RAID controller as a spare or to replace damaged cables
[3]This SD card is blank.
[4]This part should be ordered with the purchase of each optional or spare Intel Xeon E5-2600 v3 CPU processor kit

PCIe Card Compatibility

PCIe Cards Twinax Cables Cisco SFP Modules
SFP-10G-SR SFP-10G-LR DS-SFP-FC8G-SW
Converged Network Adapters (CNAs)
UCSC-PCIE-BSFP (Broadcom 57712 Dual Port 10Gb SFP+ w/TOE iSCSI) Yes Yes No
UCSC-PCIE-CSC-02 (Cisco VIC 1225 Dual Port 10Gb SFP+ CNA) Yes Yes Yes No
UCSC-PCIE-C10T-02 (Cisco VIC 1225T Dual Port 10GBaseT CNA) No No No No
UCSC-MLOM-CSC-02 (Cisco UCS VIC1227 VIC MLOM - Dual Port 10Gb SFP+) Yes Yes Yes No
UCSC-MLOM-C10T-02 (Cisco UCS VIC1227T VIC MLOM - Dual Port 10GBaseT) No No No No
UCSC-PCIE-C40Q-02 (Cisco VIC 1285 Dual Port 40Gb QSFP CNA) Yes No [1] No
UCSC-PCIE-C40Q-03 (Cisco VIC 1385 Dual Port 40Gb QSFP+ CNA w/RDMA) Yes No [1] No
UCSC-PCIE-ESFP (Emulex OCe11102-FX dual-port 10 GbE FCoE CNA (Gen 3 CNA)) Yes Yes No
UCSC-PCIE-QSFP (QLogic QLE8242-CU dual-port 10 GbE FCoE CNA) Yes Use Qlogic SFP
UCSC-PCIE-B3SFP (Broadcom 57810 10Gb A-FEX SFP+ Yes Yes No
UCSC-PCIE-Q8362 (Qlogic QLE8362 dual-port 10 GbE FCoE CNA) Yes Use Qlogic SFP
UCSC-PCIE-E14102 (Emulex OCe14102-UX dual-port 10 GbE FCoE CNA) Yes Yes No
Converged Network Adapters (CNAs)
N2XX-ABPCI01-M3 (Broadcom 5709 Dual-Port Ethernet PCIe Adapter for M3 Servers) Use RJ45 Ethernet cable
N2XX-ABPCI03-M3 (Broadcom 5709 Quad Port 10/100/1Gb NIC w/TOE iSCSI for M3 Servers Use RJ45 Ethernet cable
N2XX-AIPCI01 (Intel X520 Dual Port 10Gb SFP+ Adapter) Yes Use Intel SFP UCS-SFP-1WLR or UCS-SFP-1WSR
UCSC-PCIE-ITG (Intel X540 Dual Port 10GBase-T Adapter) Use RJ45 Ethernet cable
UCSC-PCIE-IRJ45 (Intel i350 Quad Port 1Gb Adapter Use RJ45 Ethernet cable
UCSC-PCIE-IRJ45 (Intel i350 Quad Port 1Gb Adapter Yes No No
Host Bus Adapters (HBAs)
N2XX-AEPCI03 (Emulex LPe 11002 Dual Port 4Gb Fibre Channel HBA No Preinstalled - do not change SFP
N2XX-AEPCI05 (Emulex LPe 12002 Dual Port 8Gb Fibre Channel HBA) No Preinstalled - do not change SFP
N2XX-AQPCI03 (QLogic QLE2462 Dual Port 4Gb Fibre Channel HBA) No Preinstalled - do not change SFP
N2XX-AQPCI05 (QLogic QLE2562 Dual Port 8Gb Fibre Channel HBA) No Preinstalled - do not change SFP
UCSC-PCIE-Q2672 (Qlogic QLE2672-CSC, 16Gb Fibre Channel HBA with SR Optics) No Preinstalled - do not change SFP
UCSC-PCIE-E16002 (Emulex LPe16002-M6, 16Gb Fibre Channel HBA with SR Optics) No Preinstalled - do not change SFP
Footnotes:
[1] This card supports a 4x10 Gbps QSFP to SFP breakout fiber cable.

Shipping Information

Express Computer Systems can ship to virtually any address in the world and provides you with the best shipping rates possible. Cost of shipping varies depending on what service you require, your destination and size of the shipment. Shipping costs will be calculated separately from your order and billed to you post purchase. In the notes section of your order please provide us with your preferred shipping method and we will get back to you.

Custom configured orders ship within 2 business days after all required products are in stock.

Please allow 3 business days for products that are not in stock to arrive to our facility in Irvine, California.

Domestic Shipments
  • Standard Ground
    • Shipping time: 2-7 business days
    • Order processing time: 0-3 business days
    • Delivery time after order is placed: 2-10 business days
    • Excludes weekends, holidays or weather delays.
  • 3 Business Days
    • Shipping time: 3 business days
    • Order processing time: 0-3 business days
    • Delivery time after order is placed: 3-6 business days
    • Excludes weekends, holidays or weather delays.
  • 2 Business Days
    • Shipping time: 2 business days
    • Order processing time: 0-3 business days
    • Delivery time after order is placed: 2-5 business days
    • Excludes weekends, holidays or weather delays.
  • Overnight / Next Business Day
    • Shipping time: 1 business days
    • Order processing time: 0-3 business days
    • Delivery time after order is placed: 1-4 business days
    • Excludes weekends, holidays or weather delays.
International Shipments
  • International Economy
    • Shipping time: 4-6 business days
    • Order processing time: 0-3 business days
    • Delivery time after order is placed: 5-9 business days
    • Excludes weekends, holidays or weather delays.
  • International Priority
    • Shipping time: 1-3 business days
    • Order processing time: 0-3 business days
    • Delivery time after order is placed: 2-6 business days
    • Excludes weekends, holidays or weather delays.

For more information on shipping view our Shipping Information page or send us a message

ECS Warranty Information

Express Computer Systems (ECS) provides a 1 year parts warranty against defects in material or workmanship that will affect the products functionality. All refurbished items are tested prior to shipping to guarantee up-time upon arrival. If you are having issues with an item we provided please Contact Us and we will do our best to assist you.

What does our ECS warranty cover?
We offer 1 year warranty as standard and additional years can be added to fit your needs. Please reach out to a sales associate via the Contact Us page or live chat for more information on extended coverage options. During the coverage period if your product fails we will offer a Next Business Day replacement. If we are unable to replace the product we will refund its original selling price. Shipping costs and tax are not refundable. Express Computer Systems retains the right to decide whether the goods will be replaced or refunded.

What is not covered by our warranty?
Our warranty does not cover any problem caused by the following conditions:

  1. accidents; misuse; carelessness; electrostatic discharge; shock; temperature or humidity beyond the specifications of the product; improper installation; operation; modification;
  2. any improper use that contravenes the instructions in the user manual;
  3. problems caused by other equipment. Our warranty is void if the product is returned with damaged, removed, counterfeit labels, or any modifications (including any component or external cover removal). Our warranties do not cover data loss or damages to any other equipment. In addition, our warranties do not cover incidental damages, consequential damages, or costs related to data recovery, removal, and installation.

Important notes:

  • Please ask for additional warranty/coverage that you may require in addition to the standard 1 ECS warranty prior to final purchase. Requesting additional warranty after your purchase can be denied.
  • FREE technical support is provided on purchased items via phone, email, or live chat.

About Express Computer Systems

Express Computer Systems is committed to transforming our customers’ IT infrastructure with high quality products at affordable costs. Our sales reps and customer support engineers understand our customers rely heavily on advanced technology to run their business but need to do so without breaking the bank.

We specialize in building custom server configurations, custom storage solutions, networking solutions, and components from top manufacturers including HPE, Dell, Cisco, NetApp, Dell EMC, HPE Nimble and many others.

Subscribe